Design note

Surface Finishing: Choosing a Finish and Writing It on the Drawing

A finish is a specification, not a colour. Thickness, adhesion, salt spray and which faces are masked all change the price and the result – and a vague note on the drawing is the most common reason a batch comes back…


1. Finish by function

The finish follows the part: copper busbars need contact plating, while sheet metal brackets usually need corrosion protection.

NeedFinishTypical spec
Electrical contact, low resistanceSilver or tin platingSilver 1-5 µm; tin 3-10 µm
Indoor corrosion, low costZinc plating, clear passivation5-10 µm
Outdoor or washdownPowder coat60-100 µm, salt spray per customer spec
Wear surfaceHard anodising or electroless nickelAnodising 15-25 µm; Ni-P 10-25 µm
Cosmetic aluminiumAnodising, natural or dyed5-15 µm
Stainless, no coatingPassivation or electropolishPer ASTM or customer standard

2. Masking is the hidden cost

  • Every masked area is manual work. A drawing with four separate contact pads costs more than one with a continuous window.
  • Threads, sealing faces, datums and press-fit bores normally stay bare – say so if they must.
  • Powder coat builds thickness: a coated bore is smaller, and a coated thread will not take a bolt.
  • If a part is plated and then bent, the coating can crack at the bend – finish after forming unless the spec says otherwise.

3. What to write on the drawing

  • Finish name and standard (for example “zinc plating, clear passivation, 8-12 µm”)
  • Thickness with a range, and where it is measured
  • Which faces are masked or left bare
  • Salt spray requirement in hours, if you have one
  • Colour reference for powder coat (RAL) and gloss level
  • Whether the finish is applied before or after assembly

4. What can go wrong

  • Hydrogen embrittlement on high-strength steel after acid pickling or plating – requires baking and a note on the drawing.
  • Poor adhesion where the surface was not degreased, or where a previous finish was not stripped.
  • Colour drift between batches of powder coat – fix one RAL and one supplier.
  • Oversized holes after plating on a precision bore – mask it, or allow for the coating.

Frequently asked questions

  • Do you finish in house? — Some processes run in house and others through qualified partner shops. When a partner is used, it is named before the order and the same documentation applies.
  • Can I get the coating thickness measured? — Yes – coating reports state thickness, adhesion and salt spray hours. Ask for the report with the quotation, not after the shipment.
  • Will plating change my dimensions? — Yes, by the coating thickness on each surface. A 10 µm coating adds 20 µm across a diameter. Precision bores should be masked or allowed for.

Related

  • Terminals and contacts — Plating thickness and contact faces controlled, not assumed.
  • Quality and documents — Coating reports, salt spray hours and what ships with each batch.

More guides on this

  • Copper busbar: thickness, plating and joint faces — The companion note for the next decision on the same part.
  • Sheet metal design: bend relief and hole-to-bend — The companion note for the next decision on the same part.
  • Die casting design guide — Wall thickness, draft and cost for cast housings.

Send the finish spec with the drawing

Thickness, masking and salt spray quoted as separate lines, so the finish is a number you can compare – within one business day on weekdays.

Send drawings. Get a reviewed quote.

One business day response, engineering comments included. No account needed.

MOQ from prototype to seriesNDA on requestlesley@livoelectrical.com