DFM review on every quote · Sample approval before mass productionMon–Fri · lesley@livoelectrical.com

Design note

Copper busbar design: thickness, plating and joint faces

A busbar fails for three reasons: too thin for the current, plating that will not survive the assembly, or a joint face that no press will ever make flat. This note covers what to decide before you send the drawing.


Thickness is a current decision, not a cost decision

Thickness sets resistance and heat. Thinning a busbar to save copper moves the heat into the joint and into whatever it is bolted to, and it is usually the plating that shows the damage first.

If the current density is already fixed by the pack design, the useful question is not “can you go thinner” but “which faces must be flat and plated” – that is what decides whether the joint runs cool.

  • 0.5 – 1.0 mm: laminated packs, cell-level links, short runs between modules
  • 1.5 – 3.0 mm: module and pack level busbars, the common range for EV packs
  • 4.0 – 6.0 mm: high-current runs, terminals with machined joint faces
  • Above 6 mm: usually cut from plate and machined, not sheared and bent

C11000 or C18150

C11000 (ETP copper) is the default: highest conductivity and the easiest to bend and plate. C18150 (chromium zirconium copper) keeps more strength after bending and after thermal cycling, at a small conductivity penalty. If the busbar is a spring element or sees vibration, C18150 is usually worth the difference; for a flat link between two fixed terminals it rarely is.

For the parts at each end of the joint, see custom metal terminals and battery cell connectors .

AlloyUse it whenWatch out for
C11000Flat and stepped links, laminated packs, plated jointsSoftens after bending; long runs need support
C18150Spring contacts, vibration, high cyclingLower conductivity – check the section
C2680 brassTerminals and contacts where conductivity is secondaryNot a substitute for copper in a power path

Plating: where, how thick, and what is masked

Plating exists for the joint, not for the looks. Silver gives the lowest contact resistance; nickel is harder and survives more mating cycles; tin is the cheapest and the first to creep under heat. State the thickness in micrometres and the areas to be left bare – a fully plated busbar that should have been masked at the weld pads is a rework order.

Masking is the cost driver: every masked area is a manual step. If the drawing shows one continuous plated window instead of four separate pads, the price drops and the joint quality does not.

  • Silver 1 – 5 µm on contact areas, masked elsewhere
  • Nickel 3 – 10 µm where wear or corrosion dominates
  • Tin 1 – 10 µm for indoor, low-cycle joints
  • Nickel under silver where the part sees heat cycles before assembly

The joint face is a flatness requirement

A busbar joint conducts through the contact area. Bending, deburring and plating all move that face. Two practical rules:

If the joint sits under a bolt with a small washer, the effective contact area is smaller than the pad you drew. The pad should be sized to the washer, plus a margin for positional tolerance of the hole.

  • Keep the joint face at least 2.5 x thickness away from the nearest bend so the bend radius does not lift it
  • Specify flatness on the joint face only, not on the whole part – a blanket flatness callout is either unmeasurable or expensive

Tolerances we hold on busbars

The full table, including stamping and CNC, is on the tolerances page .

FeatureStandardAchievable with effortWhat drives the cost
Laser cut profile±0.10 mm±0.05 mm on thin contoursNesting, thickness, edge quality
Bend position±0.10 mm±0.05 mm on short flangesSpringback control, fixtures
Hole position±0.10 mm±0.05 mm with a jigDatum scheme, drill vs laser
Joint face flatness0.05 mm0.02 mm on machined facesMachining allowance, fixture
Plating thickness±1 µm on target±0.5 µm on silverBath control, racking

What to put on the drawing

  • Alloy and temper, plus the thickness with its tolerance
  • Which faces are plated, the plating thickness, and the mask areas
  • Datum scheme – pick one hole as the datum, not the outline
  • Flatness on joint faces only, with the mating washer size if it matters
  • Bend radius and bend direction, including which way each bend goes
  • Any insulation: heat shrink, powder coat, laminated film – and the temperature the part will see

Frequently asked questions

  • Can you quote one busbar as a prototype? — Yes. Prototypes from one piece are quoted regularly, cut and bent from plate without dedicated tooling. Unit price is higher because setup and plating have a minimum charge.
  • Do you plate in house? — Silver, nickel and tin plating are run in house or by named partner shops depending on the process; either way the thickness is measured and reported per batch.
  • How flat can a bent busbar joint face be? — 0.05 mm as standard, 0.02 mm if the face is machined after bending. Ask for a first article report with the flatness measured on the face, not on the whole part.
  • Can I get the parts without plating? — Yes, and for several projects that is the right choice – the buyer plates locally. State it on the drawing and we quote the cut and formed part only.

Related

  • Copper busbars — Thickness 0.5-6 mm, C11000 and C18150, plated and masked.
  • Application note: EV module busbar — How the process changes with volume, and why the joint face decides yield.

Send the busbar drawing and get the joint faces quoted properly

Price, lead time and DFM notes in writing within one business day on weekdays. First reply from a named engineer within 4 working hours.

More guides on this

  • Metal stamping: what decides the die and the price — The companion note for the next decision on the same part.
  • Surface finishing: choosing a finish and writing it on the drawing — The companion note for the next decision on the same part.
  • Busbar weight and current calculator — Size a copper busbar before you specify it.
  • Laser cutting design guide — Kerf, holes and cost for cut parts.

Send drawings. Get a reviewed quote.

One business day response, engineering comments included. No account needed.

MOQ from prototype to seriesNDA on requestlesley@livoelectrical.com