DFM review on every quote · Sample approval before mass productionMon–Fri · lesley@livoelectrical.com
Heat sink for a sealed enclosure: fins versus the interface

Case study

Heat sink for a sealed enclosure: fins versus the interface

Adding fins is the obvious answer to a hot component and often the wrong one. In a sealed box the limiting factor is usually the interface between the device and the sink, not the fin area on the outside.

The figures describe the representative case discussed in this note, not a specific customer order.

VolumePrototype through serial
MaterialExtruded or machined aluminium, sealed IP enclosure
RouteMachined, drilled and tapped to the interface
Control that decides itFlatness on the mounting face and the interface material before any added fin area

The situation

A power module sits on a machined aluminium sink inside a sealed IP-rated enclosure. The first build runs hot even though the fin stack matches the thermal model. Measured, the sink’s mounting face is out by 0.15 mm across the footprint, the thermal pad is compressed on one edge only, and the extra fins are radiating into still air inside the box.

What actually moves the temperature

Extruded sinks hold fin geometry cheaply; machined sinks hold flatness and mounting features. Knowing which one is doing the work is the design decision.

ChangeEffectCost
Flatness 0.15 → 0.05 mm on the mounting faceFull pad contact instead of a lineMachining pass; no new tooling
More fins inside still airLittle to noneMaterial and extrusion time
Thicker base, thinner finsSpreads heat to the outer finsExtrusion profile change
Thermal interface material changeOften the largest single gainPurchased part, no machining

What we would change in the drawing

  • Flatness on the mounting face, with the measurement area stated – not “flat”
  • Base thickness and fin thickness as separate dimensions, so the tool can be checked
  • Whether the sink is extruded or machined from plate, and the cut length
  • Surface treatment: anodising adds a layer; say whether the mounting face must stay bare

Send the sink drawing and the thermal requirement

Heat load, ambient and the interface material – the DFM note comes back with the flatness and finish call on the mounting face.

Frequently asked questions

  • What flatness can you hold on a machined mounting face? — 0.05 mm across the mounting area is standard on a machined face; 0.02 mm is achievable with a finishing pass. Extruded faces hold less without machining.
  • Does anodising hurt the thermal path? — An anodised layer adds resistance at the interface. If the device mounts directly, leave the mounting face bare or specify a masked area.
  • Can you bond or press fins into a base? — Yes, bonded and skived assemblies are quoted where the fin density is beyond what an extrusion profile can hold.

Related

  • Heat sinks and plates — The part family this note is about.
  • Design guide: heat sink — Fin geometry, flatness and the interface.