Electrical terminal: where contact resistance is decided

Case study

Electrical terminal: where contact resistance is decided

A terminal that fits is not a terminal that works. Plating thickness at the contact face, burr on the mating edge and the flatness of a screw pad decide resistance and heat – and all three are cheap to specify before the first batch.

The figures describe the representative case discussed in this note, not a specific customer order.

Volume50,000 per year
Material0.8 mm C11000 copper, silver 1–5 µm on the contact pad
RouteStamping, two bends, selective plating with masking
Control that decides itPlating thickness and burr limit at the contact face

The situation

Copper terminal, 0.8 mm C11000, two bends, silver plated only on the contact pad. Volume 50,000 a year. The original drawing said “silver plated” with no thickness and no masking, and the first samples ran hot on a 200 A test.

What the drawing needed

  • Plating thickness at the pad – silver 3-5 µm, measured at the contact face, not the average over the part.
  • Masking – the two bend lines stay bare so the coating does not crack in the press brake.
  • Burr limit – 0.05 mm maximum on the conductor edge; a burr concentrates current and can puncture insulation.
  • Contact face roughness – Ra 0.8 µm or better at the pad, which means the die that punches it matters.
  • Bend radius – at least 1x thickness, or the copper work-hardens and the spring-back varies batch to batch.

What we measure, and how often

CheckMethodFrequency
Plating thicknessXRF at the pad and at a masked edgePer batch
Contact resistanceFour-wire measurement on a sample pairFirst article and per batch on request
Burr heightProfile projector or microscopePer batch
DimensionalCMM on hole pattern and bend angleFirst article, then per control plan

Related

  • Surface finishing guide — Finish by function, masking cost and how to write it down.
  • Terminals and contacts — Plating thickness and contact faces controlled, not assumed.

Send the terminal drawing with the resistance target

Plating, masking and inspection as separate lines – within one business day on weekdays.

Send drawings. Get a reviewed quote.

One business day response, engineering comments included. No account needed.

MOQ from prototype to seriesNDA on requestlesley@livoelectrical.com